POWER LIGHT
OPC LIGHT
ERROR TYPE
REPAIR
-
-
AC Power failure
Loose connection, Power Unit or Main Unit
1(1/sec)
-
Lamp Failure
Loose connection to Inverters, reload firmware, Inverter Unit or LCD Panel
2X
-
Power Failure
Inverter Unit or LCD Panel
2X
1X
13V/UR10V failure
Power Unit or Main Unit
2X
2X
3.3V Main Failure
Power Unit or Main Unit
2X
3X
UR6V failure
Power Unit or Main Unit
2X
5X
Panel 5V failure
LCD Control Unit or LCD Panel
2X
7X
CPU Communication
Main Unit or LCD Controller
2X
7X
Audio Amp Error
Loose/Damaged speaker wires, Terminal Unit
2X
8X
LCD Control ROM Error
Main Unit or LCD Control Unit
3X
1X
Communication
Main Unit
3X
2X
Main Failure
Main Unit or LCD Control Unit
3X
3X
Communication
Main Unit
4X
-
Vsync Error
Reseat cables, Main Unit
5X
-
Monitor Temp Failure2
Main Unit
6X
-
BD Unit Error
BD Unit
8X
-
Flash Rom Error
Main unit or reload firmware